Remote Sense |
Load-line loss compensation for models <= 100V is 10% above full scale voltage total (5% per load-line), and models > 100V is 4% above full scale voltage total (2% per load-line). |
Parallel Operation |
Up to 5 units may be paralleled for additional current within the power supply single-unit specifications, with exception of the DC output current set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory. |
Series Operation |
Up to 2 units (See Output Float Voltage) | |
| |
|
|
Nominal Voltage 3 phase, 3 wire + ground |
208/220 VAC (operating range 187 - 242VAC) 380/400 VAC (operating range 342 - 440VAC) 440/480 VAC (operating range 396 - 528VAC)* *Optional |
Frequency |
47 – 63Hz |
Power Factor |
>0.9 typical at 208/220 VAC input >0.78 typical at 380/400 VAC input >0.69 typical at 440/480 VAC input |
Protection |
½ cycle ride-though on all three phases, 3 cycle ride-through on single phase; missing phase shutdown | |
| |
|
Input: AC Voltage and Current | |
Output Power |
Max AC Input Current (A) per Phase, Low Line |
187-242 VAC |
342-440 VAC |
396-528 VAC |
5kW (3U) |
21 |
14 |
13 |
10kW (3U) |
41 |
27 |
26 |
15kW (3U) |
62 |
40 |
39 |
20kW (6U) |
83 |
54 |
52 |
25kW (6U) |
103 |
67 |
65 |
30kW (6U) |
124 |
80 |
78 | |
| |
|
Output: Voltage and Current Ranges | |
|
3U |
6U |
Ripple & Noise |
Power |
5 kW |
10 kW |
15 kW |
20 kW |
25 kW |
30 kW |
rms (20Hz-300kHz) |
p-p |
Voltage |
Current |
40 |
125 |
250 |
375 |
500* |
625* |
750* |
20mV |
75mV |
60 |
83 |
167 |
250 |
333 |
417 |
500 |
20mV |
75mV |
80 |
63 |
125 |
188 |
250 |
313 |
375 |
20mV |
100mV |
100 |
50 |
100 |
150 |
200 |
250 |
300 |
20mV |
100mV |
160 |
31 |
63 |
94 |
125 |
156 |
188 |
25mV |
150mV |
200 |
25 |
50 |
75 |
100 |
125 |
150 |
25mV |
175mV |
250 |
20 |
40 |
60 |
80 |
100 |
120 |
30mV |
200mV |
330 |
15 |
30 |
45 |
61 |
76 |
91 |
30mV |
200mV |
400 |
12 |
25 |
38 |
50 |
63 |
75 |
30mV |
300mV |
600 |
8 |
17 |
25 |
33 |
42 |
50 |
60mV |
350mV | |
| |
* By way of paralleling 5kW, 10kW & 15kW supplies |
|
|
Ripple & Noise (Voltage Mode) |
See Output: Voltage & Current Ranges Chart Above. Ripple and noise specified at full load, nominal AC input |
Ripple (Current Mode) |
<+/- 0.04% of full scale rms current |
DC Voltage Slew Rate |
100 msec 5-95% of full scale typical (Contact factory for model specific slew rates) |
DC Current Slew Rate |
45A / ms typical |
Line Regulation |
(±10% of nominal AC input, constant load) Voltage Mode: +/- 0.01% of full scale Current Mode: +/- 0.05% of full scale |
Load Regulation |
(no load to full load, nominal AC input) Voltage Mode: +/- 0.02% of full scale Current Mode: +/- 0.1% of full scale |
Load Transient Response |
Recovers within 1ms to +/-0.75% of steadystate output for a 50% to 100% or 100% to 50% load change |
Efficiency |
87% typical at nominal line and max load |
Stability |
±0.05% of set point after 8 hrs. warm-up at fixed line, load and temperature |
Temperature Coefficient |
0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output current rating for current set point |
Output Float Voltage |
Negative terminal within +/- 150 V of chassis potential | | |
|
Dimensions |
Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) |
|
Height: 5-15 kW Units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm) | |
|
|
Weight |
3U, 5kW ~ 40 lbs (18kg) 3U, 10kW ~ 60 lbs (27kg) 3U, 15kW ~ 80 lbs (36kg) 6U, 20kW ~ 120 lbs (54kg) 6U, 25kW ~ 140 lbs (63kg) 6U, 30kW ~ 160 lbs (72kg) |
Shipping Weight |
3U, 5kW ~ 70 lbs (32kg) 3U, 10kW ~ 90 lbs (41kg) 3U, 15kW ~ 110 lbs (50kg) 6U, 20kW ~ 150 lbs (68kg) 6U, 25kW ~ 170 lbs (77kg) 6U, 30kW ~ 190 lbs (86kg) | |
Programming & Read-back Specifications | |
|
Programming |
Read-Back / Monitoring |
|
Accuracy |
Resolution |
Accuracy |
Resolution |
Front panel Display |
SGA: +/- (0.5%fs + 1 digit) SGI, Voltage: +/- 0.1% of full scale SGI, Current: +/- 0.4% of full scale |
SGA: 3.5 digits SGI: 4.0 digits |
SGA: +/- (0.5%fs + 1 digit) SGI, Voltage: +/- 0.1% of full scale SGI, Current: +/- 0.4% of full scale |
SGA: 3.5 digits SGI: 4.0 digits |
Knob control & Display read-back |
Remote Analog Interface |
Voltage: +/-0.25% of full scale for 0-5V range, +/-0.5% of full scale for 0-10V range Current: 0.8% of full scale |
NA |
+/-1.0% of full scale (0 - 10V) |
NA |
25-pin D-sub connector (0~5V or 0~10V) |
Remote Digital Interface |
Voltage: +/- 0.1% of full scale, Current: +/- 0.4% of full scale |
+/-0.002% of full scale |
Voltage: +/- 0.15% of full scale, Current: +/- 0.4% of full scale |
+/-0.002% of full scale |
RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet (see Options) |
OVP |
+/- 1% of full scale |
+/-0.002% of full scale |
|
|
Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs |
User I/O |
Disconnect & Polarity-reversal relay control ( Only available with Ethernet Option ) |
Digital 10-pin Molex type connector Chart Below | |
|
|
|
1 |
Isolated Remote ON/OFF |
14 |
Isolated TTL/CMOS ON/OFF Control |
2 |
Isolated Circuit Return |
15 |
Remote Voltage Programming |
3 |
Remote Overvoltage Set |
16 |
Remote Current Programming |
4 |
Voltage Return for Pins 9, 15, or 21 |
17 |
Fault State |
5 |
Remote ON/OFF |
18 |
Shutdown Fault |
6 |
Circuit Common |
19 |
Output Voltage Monitor |
7 |
Output Current Monitor |
20 |
Voltage Return for Pins 9, 15, or 21 |
8 |
Local Voltage Control Monitor |
21 |
Voltage Control Resistance |
9 |
Remote Voltage Programming |
22 |
Current Control Resistance |
10 |
Remote Current Programming |
23 |
Current Return for Pins 10, 16, or 22 |
11 |
Local Current Control Monitor |
24 |
Circuit Common |
12 |
60V Remote Sense |
25 |
Current Return for Pins 10, 16, or 22 | |
|
Digital User I/O Pinouts ( Ethernet Option Only ) | |
1 |
Fold Back Monitor |
2 |
Direct Shutdown |
3 |
Fault Indication |
4 |
Trigger Out |
5 |
Common |
6 |
Polarity output reversal signal |
7 |
Isolation relays relay open signal |
8 |
Sense relays open signal |
9 |
Common |
10 |
Trigger in | |
|
|
|
|
|
|
|
|
|
|
|
|
|
Descripcion
High Power Density: Up to 15 kW in a 3U / 30 kW in a 6U chassis
Wide Voltage Range: 0-40V up to 0-600V, in increments of 5 kW from 5 to 30 kW
Fast Load Transient Response: Protection from undesired voltage excursions
Low RMS and P-P Noise: Suitable for the most sensitive applications
Parallelable up to 150 kW: Expandable as your requirement grows
Modular Design: Upgradeable for the ultimate in investment protection
Sequencing: Program custom waveforms
Easy-to-read Fluorescent Display: SGI supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
Ethernet Control: LXI Class C compliant communication through integrated web server
Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
Hardware Trigger: Ethernet Option Only
5 Year Warranty
Applications
Process Control Whether you are controlling ion beams for the manufacturer of semiconductors, or driving a solution for precise control in a plating process, the SG series is an ideal choice with it’s small size, reliable modular design and standard analog programmability. Direct control of V and I along with 0-10V outputs allowing monitoring of the actual voltage and current, provides a simple interface for your PLC or other type of analog controller.
Product Development Testing & Burn-in DC-DC converters, laser diodes, automotive and semiconductor components and aircraft flight hardware are just a few of the items being tested using the SG product family. From simple front panel control to complex test sequences for compliance testing, the SG series will grow with your product needs.
Research A research environment presents some of the most demanding requirements on your test instrumentation. Equipment that is sufficient today, may not meet the needs of the next project. With the SG series this is no longer a problem. The modular design allows you to easily upgrade to higher power levels in the future, or parallel units to achieve up to 150 kW. With the sophisticated sequencing capability of the SGI model, you can build an infinite variety of test or diagnostic programs and have them execute directly from the power supply.
Automotive Component Test The 16-bit resolution of the Ethernet programming and hardware triggering allows for detailed sequencing associated with battery fluctuation simulation. The tight load regulation capability of the SG series makes it a superior source for validation and acceptance testing and burn-in of automotive components. The 40V models, in particular, provide a full range of testing to simulate battery conditions. Margin testing of 12V and 14V nominal components, such as electronic control units (ECU) and electromechanical components, is easily achieved.
Rackmount ATE Systems The high power density of the SG series makes it ideal for ATE System integration. The wide variety of voltage and current combinations in 3U and 6U heights allows multiple voltage outputs in a small amount of space. The wide variety of control methods possible, allows easy integration into legacy systems as well as high speed systems.
Battery Charging The SG series provides high accuracy voltage output to optimize battery charging. Battery charging requires high accuracy voltage and stable current output for fast bulk and absorption phase charging and high accuracy and stable voltage for float charging to avoid “gassing” the battery. With the remote interface options, the charging process can easily be automated for volume production.
The SG series represents the next generation of high power programmable DC power supplies. Designed for exceptional load transient response, low noise and the highest power density in the industry. The industry leading power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.
At the heart of the SG series is a 5 kW modular supply. Depending on the output voltage, one to six modules can be configured in a single chassis to deliver 5 kW to 30 kW of power. These chassis can then be easily paralleled to achieve power levels up to 150 kW. Paralleled units operate like one single supply providing total system current. Available in two control versions, the SGA has basic analog controls, while the SGI provides intelligent control features
|
|
|
|
|
|
|
|
|