Model
|
AFV-33015
|
AFV-33020
|
AFV-33030
|
AFV-33045
|
AFV-33060
|
AFV-33075
|
AFV-33100
|
AFV-33120
|
AFV-33150
|
AFV-33200
|
AFV-33300
|
AFV-33400
|
Capacity(kVA)
|
15
|
20
|
30
|
45
|
60
|
75
|
100
|
120
|
150
|
200
|
300
|
400
|
Circuit Type
|
IGBT/PWM Type
|
Input
|
Phase
|
Three Phase
|
Voltage
|
120V/208V, 220V/380V or
277V/480V *
|
Voltage
range
|
220V/380V ¡À 15%
|
Frequency
range
|
47
̴ 63 Hz
|
Power
Factor
|
0.9
|
Max.current(A) (With full load)
|
28.1
|
37.4
|
56.1
|
84.2
|
112.2
|
140.3
|
187.1
|
224.5
|
280.6
|
374.1
|
561.2
|
748.2
|
Output
|
Phase
|
Three Phase
|
Wave
|
SINE Wave
|
Voltage
|
Low(V)
|
0V
̴ 150.0v (L-N)
|
High(V)
|
150.1V ̴ 300.0V (L-N)
|
Frequency
range
|
|
45
̴ 65 Hz. Optional 45 ̴ 500 Hz
|
Frequency
regulation
|
|
¡Ü 0.01%
|
Max.
Current (A)
|
High(A)
|
20.8
|
27.8
|
41.7
|
62.5
|
83.3
|
104.2
|
138.9
|
166.7
|
208.3
|
277.8
|
416.7
|
555.6
|
Low(A)
|
41.7
|
55.6
|
83.3
|
125
|
166.7
|
208.3
|
277.8
|
333.3
|
416.7
|
555.6
|
833.3
|
1111.1
|
System
|
Line
regulation
|
|
< 1%
|
Load
regulation
|
|
¡À 1 % (linear load)
|
THD
|
|
¡Ü 2% (linear load)
|
Efficiency
|
|
¡Ý 90%
|
Response
time
|
|
¡Ü 2mS
|
Crest
Factor
|
|
3:1
|
Protection
|
|
Input no-fuse
breaker, electronic circuit instant trip for over/low voltage, over current,
over load, over temperature and short circuit protection and alarm system
|
Readings
|
Dsiplay
|
|
VFD(Touch screen Option)
|
Voltage
|
|
Res.: 0.1V,
Accuracy: 0.5%FS+4Counts.
|
Current
|
|
Res.: 0.1A,
Accuracy: 0.5%FS+4Counts.
|
Frequency
|
|
Res.: 0.1Hz,
Accuracy: 0.5%FS+4Counts.
|
Control mode
|
RS-232
|
|
Standard
|
RS-485
|
|
Standard
|
GPIB
|
|
Option
|
Safety
|
Insulation
resistance
|
|
10M
ohm(Tested with DC 500V)
|
Insulation
withstand voltage
|
|
Tested with
AC 1,800V 10mA for 1 min
|
Environment
|
Cooling
system
|
|
Fan Cooling
|
Temperature
(Operating)
|
|
0¡ãC
̴ 45¡ãC
|
Humidity
(Operating)
|
|
0
̴ 90% (Non-condensing)
|
Altitude
(Operating)
|
|
< 1500m
|
Dimensions
(W*D*H) mm
|
650x920x1248
|
700x800x1620
|
940x820x1700
|
1100x940x1850
|
1400x1040x2000
|
Weight(kg)
|
400
|
415
|
425
|
435
|
490
|
525
|
716
|
777
|
1300
|
1400
|
2200
|
2500
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Descripcion
La serie de fuentes de poder de corriente alterna de AC Power Preen, tienen las siguientes caracteristicas comunes:
- Pantalla de control sensible al tacto VFD, de gran robustes para ambientes extremos como -20 oC a +85 oC
- Alta eficiencia, mayor al 90%, lo cual asegura ahorro de energ¨ªa y ecologicamente amigable
- Salida de voltaje y frecuencia programable.
- De manera opcional se puede tener una salida en modo de pasos, modo de cambio gradual y salida simulanda de manera curveada, de acuerdo a las necesidades del cliente para cumplir estandares especificos
- Multiples puertos de comunicaci¨®n a escoger: RS232, RS485, USB, GPIB.
- Soporte para programacion con comandos SCPI y ambientes de programacion LabView y MODBUS
- Funci¨®n de incio gradual para diseño y prueba de motores electricos
- Autodiagnostico de fallas, facilita el mantenimiento y reduce los paros de producci¨®n
- Proteccion contra regreso de sobre voltaje, la fuente apaga su salida para proteger el equipo de carga y mantener la seguridad
- Limitador de potencia de salida ajustable
- De manera opcional se puede ajustar el voltaje de salida de cada fase de manera independiente
- Opcionalmente se pueden tener dos unidades operando de manera paralela
- Ventiladores de velocidad variable para manetener la eficiencia de energia y reducir el ruido
- Dependiendo del modelo la potencia de salida puede ser desde 15 kVA a 2000 kVA
|
|
|
|
|
|
|
|
|