Measurement Modes | LCR and continuous measurement | Measurement Parameters | Z, Y, ƒÆ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanƒÂ), ƒÐ, ƒÃ | Measurement Range | 100 mohms to 100 Mohms, 10 ranges (All parameters are determined according to Z) | Display Range | Z: 0.00 m to 9.99999 Gohms, Rs, Rp, Rdc, X: }(0.00 m to 9.99999 Gohms) G, B: }(0.000 n to 9.99999 GS), Ls, Lp: }(0.00000 ƒÊ to 9.99999 GH), Cs, Cp: }(0.0000 p to 9.99999 GF), Y: 0.000 n to 9.99999 GS, ƒÆ : }(0.000‹ to 999.999‹), Q: }(0.00 to 9999.99), D : }(0.00000 to 9.99999), ƒ¢ % : }(0.000 % to 999.999%) | Basic Accuracy | Z }0.05% rdg. ƒÆ: }0.03‹ (represestative value, Measurable range: 1 mohms to 200 Mohms) | Measurement Frequency | 4 Hz to 8 MHz (10 mHz to 100 Hz steps) | Measurement Signal Level | [Normal mode: V mode/CV mode] 4 Hz to 1.0000 MHz: 10 mV to 5 V (maximum 50 mA) 1.0001 MHz to 8 MHz: 10 mV to 1 V (maximum 10mA) [Low impedance high accuracy mode: V mode/CV mode] 4 Hz to 1.0000 MHz: 10 mV to 1 V (maximum 100 mA) [Normal mode: CC mode] 4 Hz to 1.0000 MHz: 10 ƒÊA to 50 mA (maximum 5 V) 1.0001 MHz to 8 MHz: 10 ƒÊA to 10 mA (maximum 1 V) [Low impedance high accuracy mode: CC mode] 4 Hz to 1.0000 MHz: 10 ƒÊA to 100 mA (maximum 1 V) [DC resistance measurement] Measurement signal level: Fixed at 1 V | DC Bias Measurement | Generating range: DC voltage 0 V to 2.50 V (10mV resolution) In low Z high accuracy mode: 0 V to 1 V (10 mV resolution) | Output Impedance | Normal mode: 100 ohms, Low impedance high accuracy mode: 10 ohms | Display | 5.7-inch color TFT with touch panel | Functions | Comparator, BIN measurement (10 categories for 2 measurement parameters), Trigger function, Open/short compensation, Contact check, Panel loading/saving, Memory function | Interfaces | EXT. I/O( HANDLER) ,USB, USB flash drive, LAN, GP-IB, RS-232C, BCD | Power Supply | 100 to 240 V AC, 50/60 Hz, 50 VA max. | Dimensions and Mass | 330 mm (12.99 in) W ~ 119 mm (4.69 in) H ~ 230 mm (9.06 in) D, 4.2 kg (148.1 oz) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Descripcion
Alta exactitud: (0.05% rdg +/-). Alta velocidad: Tiempo de respuesta de 1ms. Rango de exactitud garantizada desde 1mohm. Mediciones de baja impedancia con repetibilidad inigualable. Frecuencia variable desde 4Hz a 8MHz. Voltaje variable desde 10mV a 5V. Corriente variable de 10 uA a 100mA. La función DC bias mide bajo condiciones simulando uso actual. Calcula las constantes dieléctrica y de conductividad. Software de aplicación gratuito e interfase PC. Función de medición continua. Guarda pantallas y las carga rápidamente. Soporte de la unidad flash USB. Función de proteccin de carga residual.
|
|
|
|
|
|
|
|
|