Testing voltage |
1000 V DC |
Rated resistance |
2000 MĦ |
Accuracy 1st effective measuring range |
}5 % of indicated valu 2 to 1000 MĦ |
Lower limit resistance |
1 MĦ (measurement resistance value to be maintained testing voltage) |
Overload protection |
1200 V AC (10 sec.) |
AC voltage measurement |
0 to 600 V (50/60 Hz), }5 % of maximum scale value accuracy, 500 kĦ or more input resistance |
Other functions |
Bright LED luminous scale, Drop proof (on concrete, 1 m/1 time), Battery check, Live circuit check, Auto discharge |
Power consumption |
AA alkaline (LR6) battery ~ 4, Continuous use: 15 hours (at 500 V range, no load) |
Dimensions, mass |
159 mm (6.26 in)W ~ 177 mm (6.97 in)H ~ 53 mm (2.09 in)D, 610 g (21.5 oz), (including battery, not including test lead) |
Accessories |
Test lead 9787 ~ 1, Operation manual ~ 1, Shoulder strap ~ 1, AA alkaline battery (LR6) ~ 4 |
Testing voltage |
1000 V DC |
Rated resistance |
2000 MĦ |
Accuracy 1st effective measuring range |
}5 % of indicated valu 2 to 1000 MĦ |
Lower limit resistance |
1 MĦ (measurement resistance value to be maintained testing voltage) |
Overload protection |
1200 V AC (10 sec.) |
AC voltage measurement |
0 to 600 V (50/60 Hz), }5 % of maximum scale value accuracy, 500 kĦ or more input resistance |
Other functions |
Bright LED luminous scale, Drop proof (on concrete, 1 m/1 time), Battery check, Live circuit check, Auto discharge |
Power consumption |
AA alkaline (LR6) battery ~ 4, Continuous use: 15 hours (at 500 V range, no load) |
Dimensions, mass |
159 mm (6.26 in)W ~ 177 mm (6.97 in)H ~ 53 mm (2.09 in)D, 610 g (21.5 oz), (including battery, not including test lead) |
Accessories |
Test lead 9787 ~ 1, Operation manual ~ 1, Shoulder strap ~ 1, AA alkaline battery (LR6) ~ 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Descripcion
Single range testing voltage 1000 V, Insulation meter up to 2000 MĦ
Built tough to withstand a 1-meter drop onto a concrete floor
Bright LED luminous scale
Check for live circuits and for the battery status
Hard case in a body, quick and easy storage without disconnecting the leads
|
|
|
|
|
|
|
|
|