Model | APS-33010 | APS-33015 | APS-33022 | APS-33030 | APS-33045 | APS-33060 | APS-33075 | Capacity | 10kVA | 15kVA | 22kVA | 30kVA | 45kVA | 60kVA | 75kVA | Input(AC) | Phase | Three Phase | Voltage | 208V/120V , 480V/277V form 1 | Voltage Range | ± 18% | ± 18% (25% Option) | Frequency | 47Hz ~ 63Hz | Power Factor | 0.95 ~ 1 | Output(AC) | Phase | Three Phase | Voltage | 208V/120V , 480V/277V form 1 | Frequency | Same as Input Frequency | Power Factor | ± 0.7 ~ 1 | VA Efficiency | ≥ 98% Full Load / No Load energy power consumption ≤ 0.2 | Line Regulation | ± 1% ~ ± 4% | ± 1% ~ ± 2% | Load Regulation | ± 1% ~ ± 4% | ± 1% ~ ± 2% | Total Harmonic Distortion | < 1% (additional waveform distortion | Response Time | ≤ 4ms / Step | Indicator | Voltmeter | Show 0~300VAC for each phase | Ammeter | Show R.S.T. Load's Current | LED | Power abnormal , output voltage overrun (high voltage / low voltage) , auto bypass supply | Protection | Over Range | Power Auto Shut & Led Indicator
| Over Load | No Fuse Break | 150% for 15Sec , 130% for 30Sec , 110% for 300Sec | Auto Bypass | Led Indicator & Alarm | Noise Suppressors | High energy surge absorber 、LC Filter、EMI Filter (option) | R.S.T. Phase Failure | Led Indicator (option) & Alarm (option) & Auto shut off (option) | Overload Capacity | 200% for 10 seconds ; 500% for 50ms | Audible Noise | ≤ 50dB | ≤ 55dB | Cooling System | Natural cooling | Fan cooling | Connections | Terminal | Environment | Ambient | 0ºC ~ 40ºC | Humidity | 0~95% (Non-condensing) |
Model | APS-33100 | APS-33120 | APS-33150 | APS-331800 | APS-33240 | APS-3300 | Capacity | 100kVA | 120kVA | 150kVA | 180kVA | 240kVA | 300kVA | Input(AC) | Phase | Three Phase | Voltage | 208V/120V , 480V/277V form 1 | Voltage Range | ± 18% (25% Option) | Frequency | 47Hz ~ 63Hz | Power Factor | 0.95 ~ 1 | Output(AC) | Phase | Three Phase | Voltage | 208V/120V , 480V/277V form 1 | Frequency | Same as Input Frequency | Power Factor | ± 0.7 ~ 1 | VA Efficiency | ≥ 98% Full Load / No Load energy power consumption ≤ 0.2 | Line Regulation | ± 1% ~ ± 2% | Load Regulation | ± 1% ~ ± 2% | Total Harmonic Distortion | < 1% (additional waveform distortion | Response Time | ≤ 4ms / Step | Indicator | LCD | Display electrical parameters . stat of the control , memories of history events | LED | Power abnormal , output voltage overrun (high voltage / low voltage) , auto bypass supply | Protection | Over Range | Power Auto Shut off (option) & Led Indicator
| Over Load | 150% for 15Sec , 130% for 30Sec , 110% for 300Sec | Auto Bypass | Led Indicator & Alarm | Noise Suppressors | High energy surge absorber 、LC Filter、EMI Filter (option) | R.S.T. Phase Failure | Led Indicator (option) & Alarm (option) | Overload Capacity | 200% for 10 seconds ; 500% for 50ms | Audible Noise | < 45dB | Cooling System | Air force Fan | Connections | Terminal | Copper Busbar | Environment | Ambient | 0ºC ~ 40ºC | Humidity | 0~95% (Non-condensing) |
|
|
|
|
|
|
|
|
|