Model | AFC-31010 | AFC-31015 | AFC-31020 | AFC-31030 | AFC-31045 | AFC-31060 | AFC-31075 | Capacity (kVA) | 10 | 15 | 20 | 30 | 45 | 60 | 75 | Circuit Type | IGBT/PWM type | Input | Phase | Three phase | Wave | SINE WAVE | Voltage | 220V/380V | Voltage range | 220V/380V±15% | Frequency range | 50Hz±3Hz or 60Hz±3Hz | Power factor | 0.85 | Output | Phase | Single phase | Wave | SINE WAVE | Voltage | Low | 5V-150V(L-N) | High | 10V-300V(L-N) | Frequency | 47~63Hz Adjustable,50Hz,60Hz; 2F,4F,400Hz(Option) | Frequency regulation | ≦0.01% | Max. current | High (A) | 41.7 | 62.5 | 83.3 | 125.0 | 187.5 | 250.0 | 312.5 | Low (A) | 83.3 | 125.0 | 166.7 | 250.0 | 375.0 | 500.0 | 625.0 | System | Line regulation | <1% | Load regulation | ±1% (linear load) | Total harmonic distortion (THD) | 2% (linear load) | Efficiency | ≧90% | Response time | ≦2ms | Wave factor | 3:1 | Protection device | Input no-fuse breaker, electronic circuit instant trip for over/low voltage, over current, over load, over temperature and short circuit protection and alarm system | Indicator | Display | LED | Voltage | Show range: 0~600V, analytic degree: 0.1V, accurate degree: 0.15%FS+4COUNT | Current | Show range: 0~700A, analytic degree: 0.01A(<100A)/0.1A(≥100A), accurate degree: 0.2%FS+4COUNT | Power | Show range: 3kW~75kW, analytic degree: 0.01kW(<10kW)/0.1kW(≥10kW), accurate degree: 0.3%FS+4COUNT | Frequency | Show range: 0~999.9Hz, analytic degree: 0.1Hz, accurate degree: 0.1% | Environment | Insulation resistance | DC500V ≧ 20MΩ | Withstand voltage insulation | AC 1800V 5mA/ 1Min | Cooling system | Fan cooling | Temperature | 0℃~40℃ | Humidity | 0~90% (Non-condensing) | Altitude | ≦ 1500m | Case No. | ③ | ④ | ⑤ | Weight(kg) | 210 | 240 | 290 | 340 | 540 | 610 | 670 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Descripcion
AFC Serie-trifásica En monofásico Out (10 ~ 75kVA)
Características y Ventajas:- Una de las claves para el apagado cuando falla.
Velocidad de respuesta rápida: - Tiempo de respuesta: ≤2ms.
Medición precisa alta para el parámetro:
- Tensión, 0.15% FS + 4COUNT;
- Actual, 0.2% FS + 4COUNT;
- Frecuencia, 0,1%;
- Poder, 0.3% FS + 4COUNT.
Tensión de salida: - 5 ~ 300V continua ajustable. Rápidas y convenientes 3 escalas de voltaje preestablecido para la simulación de alta y baja tensión:
- Alto: + 10% ~ + 25% del voltaje preestablecido;
- Medio: voltaje preestablecido;
- Baja: -10% ~ -30% del voltaje preestablecido.
Salida de onda sinusoidal pura. (Por favor, consulte la tabla de especificaciones). Función de Protección y Alarma de fallo: - Entrada interruptor sin fusible; circuito electrónico viaje instantáneo para sobre voltaje, sobre corriente y sobre carga.
Módulo de potencia de diseño patentado:
|
|
|
|
|
|
|
|
|