Model | AFC-500W | AFC-1KW | AFC-11003 | AFC-11005 | AFC-11008 | AFC-11010 | AFC-11015 | AFC-11020 | AFC-11030 | Capacity (kVA) | 0.5 | 1 | 3 | 5 | 8 | 10 | 15 | 20 | 30 | Circuit Type | Transistor amplifier type | IGBT/PWM type | Input | Phase | Single phase | Wave | SINE WAVE | Voltage | 220V | Voltage range | 220V±15% | Frequency range | 50Hz±3Hz 或 60Hz±3Hz | Power factor | 0.85 | Output | Phase | Single phase | Wave | SINE WAVE | Voltage | Low | 0~150V(L-N) | 5V-150V(L-N) | High | 0~300V(L-N) | 10V-300V(L-N) | Frequency | 47~63Hz Adjustable,50Hz,60Hz; 2F,4F,400Hz(Option) | Frequency regulation | ≤0.01% | Max. current | High (A) | 2.1 | 4.2 | 12.5 | 20.8 | 33.3 | 41.7 | 62.5 | 83.3 | 125.0 | Low (A) | 4.2 | 8.4 | 25 | 41.7 | 66.7 | 83.3 | 125.0 | 166.7 | 250.0 | System | Line regulation | ±0.2% | <1% | Load regulation | ±0.2% | ±1% (linear load) | Total harmonic distortion (THD) | 0.2% | 2% (linear load) | Efficiency | ≧70% | ≧90% | Response time | ≦5μs | ≦2ms | Wave factor | 1.4:1 | 3:1 | Protection device | Input no-fuse breaker, output no-fuse breaker, electronic circuit instant trip for over/low voltage, over current, over load, over temperature and short circuit protection and alarm system | Input no-fuse breaker, electronic circuit instant trip for over/low voltage, over current, over load, over temperature and short circuit protection and alarm system
| Indicator | Display | LED | Voltage | Show range: 0~600V, analytic degree: 0.1V, accurate degree: 0.15%FS+4COUNT | Current | Show range: 0~700A, analytic degree: 0.01A(<100A)/0.1A(≥100A), accurate degree: 0.2%FS+4COUNT | Power | 4 COUNT digitally watt meter analytic degree: 1W | Show range: 3kW~75kW, analytic degree: 0.01kW(<10kW)/0.1kW(≥10kW), accurate degree: 0.3%FS+4COUNT | Frequency | Show range: 0~999.9Hz, analytic degree: 0.1Hz, accurate degree: 0.1% | Environment | Insulation resistance | DC500V ≧ 20MΩ | Withstand voltage insulation | AC 1800V 5mA/1Min | Cooling system | Fan cooling | Temperature | 0℃~40℃ | Humidity | 0~90% (Non-condensing) | Altitude | ≦ 1500m | Case No. | ① | ② | ③ | ④ | Weight(kg) | 44 | 89 | 73 | 89 | 200 | 210 | 240 | 280 | 330 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Descripcion
AFC Serie - Monofásico En monofásico Out (0,5 ~ 30kVA)
Características y Ventajas: - Una clave para el apagado cuando falla.
Velocidad de respuesta rápida: - ≤2ms tiempo de respuesta.
Máxima Medición precisa para el parámetro: - Tension, 0.15 % FS + 4COUNT ;
- Actual, 0.2 % FS + 4COUNT;
- Frecuencia, 0,1 % ;
- Poder, 0.3 % FS + 4COUNT.
Tensión de salida: - 5 ~ 300V continua ajustable. Rápidos y convenientes 3 escalas de voltaje preestablecido para la simulación de alta y baja tensión:
- Alto : + 10 % ~ + 25 % del voltaje preestablecido.
- Medio: voltaje preestablecido.
- Baja: -10 % ~ -30 % del voltaje preestablecido.
Salida de onda sinusoidal pura. (Por favor, consulte la tabla de especificaciones) .
Función de Protección y Alarma de fallo: - Entrada interruptor sin fusible; circuito electrónico viaje instantáneo para el sobre voltaje, sobre corriente, sobre carga, sobre temperatura y protección contra cortocircuitos y sistema de alarma.
Módulo de potencia patente de diseño.
|
|
|
|
|
|
|
|
|