CT6862 |
CT6863 |
Rated current |
50 A AC/DC |
200 A AC/DC |
Max. allowable input |
100 A continuous (requires derating at frequency or temperature) |
400 A continuous (requires derating at frequency or temperature) |
Frequency characteristics |
Amplitude: DC to 1 MHz Phase: DC to 300 kHz |
Amplitude: DC to 500 kHz Phase: DC to 300 kHz |
Amplitude and Phase accuracy |
DC ¡À0.05 % rdg. ¡À0.01 % f.s. (Phase: Not be defined) 16 Hz ¡Ü f ¡Ü 400 Hz ¡À0.05 % rdg. ¡À0.01 % f.s. (Phase: ¡À0.2 deg) Be defined to 1 MHz |
DC ¡À0.05 % rdg. ¡À0.01 % f.s. (Phase: Not be defined) 16 Hz ¡Ü f ¡Ü 400 Hz ¡À0.05 % rdg. ¡À0.01 % f.s. (Phase: ¡À0.2 deg) Be defined to 500 kHz |
Power consumption |
5 VA max. (at 50 A/55 Hz, ¡À12 V power requirement) |
6 VA max. (at 50 A/55 Hz, ¡À12 V power requirement) |
Output voltage |
2 V/rated current range (voltage output with the Sensor Unit 9555-10, use with a device having a 1 Mohm input resistance or higher) |
Max. rated voltage to earth |
AC/DC 1000 V (50/60 Hz, CAT III ) |
AC/DC 1000 V (50/60 Hz, CAT III ) |
Core diameter |
¦Õ 24 mm (0.94 in) |
¦Õ 24 mm (0.94 in) |
Operating temperature, humidity |
-30¡ãC to +85¡ãC (86¡ãF to 185¡ãF), 80% rh or less (with no condensation) |
Power requirements |
DC ¡À11 V to ¡À15 V (Power suppled via the 9555-10, 9555-10 requirement with 100 to 240 V AC) |
Dimensions, mass |
70W (2.76 in) ¡Á 100H (3.94 in) ¡Á 53D (2.09 in) mm, Cord length: 3 m (9.84 ft), 340 g (12.0 oz) |
70W (2.76 in) ¡Á 100H (3.94 in) ¡Á 53D (2.09 in) mm, Cord length: 3 m (9.84 ft), 350 g (12.3 oz) |
Supplied accessories |
Mark bands ¡Á 6, Operating manual ¡Á 1 |