Display: |
3¨ú digit liquid crystal display (LCD) with a maximum reading of 3999. |
Polarity: |
Automatic, positive implied, negative polarity indication. |
Overrange: |
(OL) or (-OL) is displayed. |
Zero: |
Automatic. |
Low battery indication: |
The ¡° ¡° is displayed when the battery voltage drops below the operating level. |
Auto power off: |
Approx. 10 minutes. |
Measurement rate: |
2 times per second, nominal. |
Operating Environment: |
0¡ÆC to 50¡ÆC / 32¡ÆF to 122¡ÆF at <70% relativehumidity. |
Storage Temperature: |
20¡ÆC to 60¡Æ / -4¡ÆF to 140¡ÆF, 0 to 80% R.H. with battery removed from meter. |
Accuracy: |
Stated accuracy at 74¡ÆF ¡¾8¡ÆF, <75% relative humidity. |
Temperature Coefficient: |
0.1 ¡¿ (specified accuracy) per ¡ÆF, (32¡ÆF to 66¡ÆF, 82¡ÆF to 122¡ÆF). |
Altitude: |
6561.7 Feet (2000m). |
Jaw opening capability: |
30mm (1.18 in) conductor. |
Power: |
1.5 volt battery x2, R03/SIZE AAA. |
DC Volts Ranges: |
400mV, 4V, 40V, 400V, 600V |
AC Volts (50Hz - 500Hz) Ranges: |
4V, 40V, 400V, 600V |
AC Current (50Hz - 60Hz) Ranges: |
40A , 400A |
Resistance Ranges: |
400§Ù, 4k§Ù, 40k§Ù, 400k§Ù, 4M§Ù, 40M§Ù |
Capacitance Ranges: |
4uF , 40uF , 400uF , 4mF |
Temperature Range: |
-30¡ÆF ~ 400¡ÆF, -35¡ÆC ~ 400¡Æ |
Continuity Range: |
400§Ù |
Non-Contact Voltage Indicator: |
Sense voltage 70V to 600VAC (50Hz ~ 60Hz) beeper chirps and big bright red LED comes on, works when meter dial is on any ranges. |
Battery Life: |
150 hours typical with carbon-zinc. 300 hours typical with alkaline. |
Size: |
306 ¡¿ 135 ¡¿ 30mm (12 ¡¿ 5.3 ¡¿ 1.2 in). |
Weight: |
Approx. 157g (1.26lb) including battery. |
Safety: |
CAT III 600 V, N10140, CE |